Boiler and Cooling Water Testing

Drop Count Series Industrial Test Kits

Drop Count Series Industrial Test Kits

All of the tests needed for industrial water control are covered by our DC Series of drop count and diskette comparator tests. The range includes acidity, alkalinity, bromine, calcium, chlorine, chloride, copper, hardness, iron, molybdate, nitrite, organophosphate, pH, phosphate, silica and zinc.

If your company is involved with industrial water treatment, you will know the importance of proper water testing. Water testing holds the key to your success. Simple, reliable on-site tests will help your clients stay in control. For you, that means good water conditions and a satisfied customer.

That’s just what is on offer from the Palintest DC Series of industrial water test kits. Whether its for boiler plant, cooling towers or chilled water systems, we provide kits you can offer to your clients with confidence. The Palintest method of modular assembly means that kits can be tailored to suit your precise requirements – designed for your system and own-branded with your company name.

Drop count tests are the simplest form of test for many industrial water parameters. Just take a sample of the water, add an indicator tablet or a drop of indicator solution, then add the test reagent drop by drop until a colour change takes place. The test result is calculated from the number of drops of reagent used. What could be easier!

Ordering Information

DescriptionProduct Code
Standard Drop Count KitSupplied in carrying case comprising sample containers, test tubes, instructions and with space to store up to 10 reagent starter packs. Reagents sold separately.PT202
Deluxe Drop Count KitSupplied in carrying case comprising sample containers and test tubes. Also includes filtration equipment for filtering industrial water samples. Reagents not included.PT204
Complete Boiler Water/Drop Count Kitincludes filter holder, papers and 50 tests each for: Alkalinity M, Alkalinity P, Chloride, Hardness, Phosphate, Sulphite, Tannin, Universal pHSP380
Complete Cooling Water/Drop Count KitContains all necessary components in a carrying case and 50 tests each for: Alkalinity P, Calcium Hardness, Chloride, Hardness, Nitrite, Organophosphate, Phenol Red, Thymol Blue.SP382
Combination Boiler/Cooling Tower Water Drop Count KitContains all necessary components, filter holder, papers, in a deluxe carrying case and 50 tests each for: Alkalinity M (2 ranges), Alkalinity P (2 ranges), Bromine, Calcium Hardness, Chloride, Hardness (2 ranges), Iron, Nitrite, Organophosphate, Phenol Red, Phosphate, Sulphite, Tannin and Universal pHSP385

Reagents

TestRange (mg/l)DescriptionProduct Code
Acidity to pH 4.50 - 1200Drop count tests (50 tests)DC506
Acidity to pH 8.30 - 1200Drop count tests (50 tests)DC502
Alkalinity M0 - 300Drop count tests (50 tests)DC510
Alkalinity M0 - 1200Drop count tests (50 tests)DC511
Alkalinity P0 - 300Drop count tests (50 tests)DC515
Alkalinity P0 - 1200Drop count tests (50 tests)DC516
Alkalinity P/OH0 - 300Drop count tests (50 tests)DC519
Alkalinity P/OH0 - 1200Drop count tests (50 tests)DC520
Calcium Hardness0 - 300Drop count tests (50 tests)DC525
Calcium Hardness0 - 600Drop count tests (50 tests)DC526
Chloride0 - 150Drop count tests (50 tests)DC533
Chloride0 - 600Drop count tests (50 tests)DC534
Hardness - Total0 - 30Drop count tests (50 tests)DC541
Hardness - Total0 - 600Drop count tests (50 tests)DC544
Hardness - Total / Organophosphonate0 - 300 (Hardness), 0 - 30 (Organophosphonate)Drop count tests (50 tests)DC548
Nitrite0 - 300Drop count tests (50 tests)DC561
Nitrite0 - 1500Drop count tests (50 tests)DC562
Sulphite0 - 150Drop count tests (50 tests)DC565
Sulphite0 - 600Drop count tests (50 tests)DC566
Tannin0 - 300Drop count tests (50 tests)DC575

Tablet Count Kits

Tablet Count Kits

Tablet Count Kits provide an extremely simple method of analysis for an important range of water parameters. The tests are particularly useful for the routine control of industrial waters such as boiler waters and cooling water systems, as well as swimming pools, natural waters and similar applications.

The tests are carried out by taking a measured volume of water and adding tablets one at a time until a prescribed colour change takes place. The result of the test is given by the number of tablets used in relation to the volume of water sample taken. A wide range of test concentrations can be measured by varying the sample size taken of the test.

The tablet count tests may be used a standalone test kits, or combined with the comparators or photometer test kits.

Test Reagents

The test tablets used in tablet count procedures contain accurately standardised titration reagents combined with specific colour indicators. In certain cases a conditioning tablet is first used to provide the correct conditions for the test. Test instructions for the individual test indicated the test reagents required and method of use.

Test Range/Sample Size

In tablet count tests, the test range depends on the sample size taken. The larger the sample size, the lower the concentration that can be measured. Similarly, the smaller the sample size, the higher the test range. The sample sizes recommended in individual test instructions are those which are most appropriate to the test ranges likely to be encountered in practice.

The maximum concentration that can be measured for each sample size is governed by the number of tablets which can be conveniently added to the water sample The most accurate result is achieved when a tablet count between four and twelve tablets is obtained. When the tablet count falls outside this number, it is recommended that a larger or smaller sample be taken as appropriate to bring the tablet count within this range.

When using small samples of 10ml or less it is desirable, once the sample has been measured out, to increase the working volume of the solution by adding deionised water (approximately 40ml) to the sample container. This is merely to aid the dissolving of the tablets and observation of the colour change. It does not effect the calculation of the test result.

Calculation of Result

The test result depends on the number of count tablets used in relation to the sample size taken. Individual test instructions give the method of calculating the test result for different sample sizes for that test.

Ordering Information

DescriptionProduct Code
Standard Tablet Count KitProvides a simple carrying case to hold up to 4 tablet reagent packs and starter packs for other tests. Complete with sample container for carrying measuring syringe for taking small volume samples. Reagents not included.PT210
Boiler Water Tablet Count Kit for Sulphite-treated systemsSP302
Boiler Water Tablet Count Kit with PhosphateSP303

Reagents

TestRange (mg/l)DescriptionProduct Code
Alkalinity M0 - 1000Replacement Packs (50 tests)AS071
Alkalinity P0 - 1000Replacement Packs (50 tests)AS073
Alkalinity P/Caustic0 - 1000Replacement Packs (50 tests)AS075
Calcium Hardness0 - 500Replacement Packs (50 tests)AS077
Chloride0 - 1000 (up to 25000 mg/l using smaller sample)Replacement Packs (50 tests)AS079
Cleaning Acid Strength0 - 10%Replacement Packs (50 tests)AS078
Cyanuric Acid0 - 200Replacement Packs (50 tests)AS087
Starter Packs (50 tests)CP087
Hardness0 - 500Replacement Packs (50 tests)AS096
Hardness LR0 - 50Replacement Packs (50 tests)AS097
Hardness VLR0 - 5Replacement Packs (50 tests)AS100
Hardness Yes/No (Control test for water softeners)4, 8 or 20Replacement Packs (50 tests)AS101
Nitrite0 - 1500Replacement Packs (50 tests)AS111
Organophosphonate0 - 20Replacement Packs (50 tests)AS158
Starter Packs (50 tests)CP158
Permanganate Value0 - 30Replacement Packs (50 tests)AS113
Starter Packs (50 tests)CP113
QAC (Quatest)0 - 500Replacement Packs (50 tests)AS165
Sulphate0 - 200Replacement Packs (50 tests)AS154
Starter Packs (50 tests)CP154
Sulphite HR & Tannin0 - 500 (Sulphite), 0 - 200 (Tannin)Replacement Packs (50 tests)AS145
Sulphite LR0 - 50Replacement Packs (50 tests)AS144
Total Alkalinity0 - 500Replacement Packs (50 tests)AS072